Overview

Ceiling Fans & Penetrations (collectively referred to as Zone Items below) represent Fixtures added to Ceilings within Zones.

Zone Items can be created using the Ceiling Fan & Penetrations Drawing Mode

Ceiling Fans

Ceiling Fans are modelled in a Hero Project to represent the air-flow cooling benefits that these devices provide to Dwellings.

The Electricity Usage of the Ceiling Fan (by default 60W) is added to the Cooling Energy of the Simulation when deriving the Star Rating result.

The Cooling benefit is simulated by adding a Ceiling Fan temperature benefit value to the Cooling thermostat setting (i.e. an additional threshold before the Cooling is turned on within the Zone in the Simulation)

Penetrations

Penetrations are modelled in a Hero Project to represent their two potential impacts on the Simulation:

  • Air Leakage due to the Penetration: As determined by the Penetration’s Type & “Sealed” property

  • Loss of Ceiling Insulation due to the Penetration: As determined by the Penetration’s Dimensions & Clearance

There are variety of Types of Penetrations available within Hero and they have various Air-Leakage values depending on their Sealed property:

Penetration Type

Sealed Air-Leakage Rate (m3/hr.fitting)

Unsealed Air-Leakage Rate (m3/hr.fitting)

Recessed Downlight

0 m3/hr

3.6 m3/hr

Exhaust Fans: I.e. Kitchen Rangehoods & Bathroom Exhaust Fans

4.0 m3/hr

20.2 m3/hr

Chimney

19.2 m3/hr

320.8 m3/hr

Other: For Other Ceiling Penetrations

0 m3/hr

10 m3/hr

Auto-Create Penetrations

Hero has a setting which allows Penetrations to be automatically added to Zones upon Zone Creation. This Setting can toggled within the Settings view.


Zone Items within the Visual-View

Selecting

You can Select a Ceiling Fan or Penetration within the Visual View. Penetrations can also be selected within the Data-Grid and this will be reflected within the Visual View.

Ceiling Fans & Penetrations also share the common context-menu actions of Select Parent (which will select the Parent Zone of the Zone Item) which can also be called by 🖱 Double Left-Clicking the Zone Item.

Zone Item Autoshift

Zone Items will automatically shift to remain with the Zone when Walls or Wall Points are moved within the Visual View. If there are no locations where the Zone Item can move to successfully, then the Wall move or Point move will be blocked.


Ceiling Fans within the Data-Grid

Property

Description

Edited Within

Quantity

Number of Ceiling Fans within the Zone

Zone Data-Grid # Column

Size

The Diameter of all Ceiling Fans within the Zone

Zone Data-Grid Size Column

Penetrations within the Data-Grid

Penetration Groups

Penetration gets grouped into Penetration Groups within the Zone Data-Grid when they share identical properties such as Width, Length, Parent Ceiling etc. This is to allow better bulk editing & visual clarity.

You can edit an individual Penetration within a Penetration Group within the Data-Grid by expanding the Group Header and changing the Individual Penetration’s property. This will then move the Penetration to a new Group.

Property

Description

Edited Within

Quantity

The Number of Penetrations with the Penetration Group

Zone Data-Grid # Column

Width

The Width (in mm) of the Penetration(s) through the Ceiling

Zone Data-Grid Width Column

Length

The Length (in mm) of the Penetration(s) through the Ceiling

Zone Data-Grid Length Column

Clearance

The Distance from the Edge of the Penetration(s) to the beginning of the Ceiling Insulation (in mm) for safety or installation requirements.

Zone Data-Grid Clearance Column

Sealed

Whether the Penetration(s) is Sealed to prevent Air-leakage as stated by the Fitting Manufacturer and specified on the Floor Plans

Zone Data-Grid Sealed Column

Space Above

The Adjacency Type of the Parent Ceiling of the Penetration or Penetration Group

Not editable

Air Leakage

The Simulated Air-Leakage of the Penetration(s) in m3/hr based on it’s Sealed property & Type

Not editable