Overview
Ceiling Fans & Penetrations (collectively referred to as Zone Items below) represent Fixtures added to Ceilings within Zones.
Zone Items can be created using the Ceiling Fan & Penetrations Drawing Mode
Ceiling Fans
Ceiling Fans are modelled in a Hero Project to represent the air-flow cooling benefits that these devices provide to Dwellings.
The Electricity Usage of the Ceiling Fan (by default 60W) is added to the Cooling Energy of the Simulation when deriving the Star Rating result.
The Cooling benefit is simulated by adding a Ceiling Fan temperature benefit value to the Cooling thermostat setting (i.e. an additional threshold before the Cooling is turned on within the Zone in the Simulation)
Penetrations
Penetrations are modelled in a Hero Project to represent their two potential impacts on the Simulation:
Air Leakage due to the Penetration: As determined by the Penetration’s Type & “Sealed” property
Loss of Ceiling Insulation due to the Penetration: As determined by the Penetration’s Dimensions & Clearance
There are variety of Types of Penetrations available within Hero and they have various Air-Leakage values depending on their Sealed property:
Penetration Type | Sealed Air-Leakage Rate (m3/hr.fitting) | Unsealed Air-Leakage Rate (m3/hr.fitting) |
---|---|---|
Recessed Downlight | 0 m3/hr | 3.6 m3/hr |
Exhaust Fans: I.e. Kitchen Rangehoods & Bathroom Exhaust Fans | 4.0 m3/hr | 20.2 m3/hr |
Chimney | 19.2 m3/hr | 320.8 m3/hr |
Other: For Other Ceiling Penetrations | 0 m3/hr | 10 m3/hr |
Auto-Create Penetrations
Hero has a setting which allows Penetrations to be automatically added to Zones upon Zone Creation. This Setting can toggled within the Settings view.
...
Zone Items within the Visual-View
Selecting
You can Select a Ceiling Fan or Penetration within the Visual View. Penetrations can also be selected within the Data-Grid and this will be reflected within the Visual View.
Ceiling Fans & Penetrations also share the common context-menu actions of Select Parent (which will select the Parent Zone of the Zone Item) which can also be called by 🖱 Double Left-Clicking
the Zone Item.
Zone Item Autoshift
Zone Items will automatically shift to remain with the Zone when Walls or Wall Points are moved within the Visual View. If there are no locations where the Zone Item can move to successfully, then the Wall move or Point move will be blocked.
...
Ceiling Fans within the Data-Grid
Property | Description | Edited Within |
---|---|---|
Quantity | Number of Ceiling Fans within the Zone | Zone Data-Grid # Column |
Size | The Diameter of all Ceiling Fans within the Zone | Zone Data-Grid Size Column |
Penetrations within the Data-Grid
Info |
---|
Penetration Groups Penetration gets grouped into Penetration Groups within the Zone Data-Grid when they share identical properties such as Width, Length, Parent Ceiling etc. This is to allow better bulk editing & visual clarity. You can edit an individual Penetration within a Penetration Group within the Data-Grid by expanding the Group Header and changing the Individual Penetration’s property. This will then move the Penetration to a new Group. |
Property | Description | Edited Within |
---|---|---|
Quantity | The Number of Penetrations with the Penetration Group | Zone Data-Grid # Column |
Width | The Width (in mm) of the Penetration(s) through the Ceiling | Zone Data-Grid Width Column |
Length | The Length (in mm) of the Penetration(s) through the Ceiling | Zone Data-Grid Length Column |
Clearance | The Distance from the Edge of the Penetration(s) to the beginning of the Ceiling Insulation (in mm) for safety or installation requirements. | Zone Data-Grid Clearance Column |
Sealed | Whether the Penetration(s) is Sealed to prevent Air-leakage as stated by the Fitting Manufacturer and specified on the Floor Plans | Zone Data-Grid Sealed Column |
Space Above | The Adjacency Type of the Parent Ceiling of the Penetration or Penetration Group | Not editable |
Air Leakage | The Simulated Air-Leakage of the Penetration(s) in m3/hr based on it’s Sealed property & Type | Not editable |