Skylights are created using the Skylight & Hole Drawing Mode

Selecting

Skylights are shown on the Visual View & Skylight Data-Grid and can be selected as per normal objects.

...

Property

Description

Edited Within

Name

The Name of the Skylight

Name Column

Type

The Type of Skylight (Skylight, Roof Window or Tubular).

Available options depend on Ceiling Assembly Type (see Type section above for more details)

Type Column

Shape

Change the Shape of the Skylight between Polygon or Circular

Shape Column

Specification

The Specification of the Skylight as per the Selected Skylight List from the Skylight Library and fitlered filtered for Type within the Data-Grid.

Various Specifications are available that changed the Glass & Frame of the Skylight.

Specification Column

Pitch

The Pitch or Incline of the Skylight on the Roof (in degrees) with 0 being Horizontal / Flat and 90 degrees being Vertical

Pitch Column

Orientation

The Direction the Face of the Skylight is facing (it’s normal face direction). Ignored if Pitch is 0 degrees.

Orientation Column

Area

The Pitched Area of the Skylight (in m2)

Not editable

Openable Percentage

Roof Windows only

The Percentage of the Roof Window’s Area that is Openable for Ventilation

Openable % Column

Internal Shade Device

Roof Windows only

The Internal Shade device for the Skylight as specified & noted on the Plans, and it’s effective R-Value, Solar Transmittance (ST) & Solar Absorptance (SA)

Internal Shading Column

External Shade Device

The External Shade device for the Skylight as specified & noted on the Plans, and it’s effective Shading Coefficient (SC)

External Shading Column

Shaft Sub-Properties

Shaft Length

Skylight & Tubular Types only

The Length of the Skylight Shaft through the Roofspace (in mm), from Centre of External Face of Skylight to Internal Face of Skylight

Shaft Length Column

Shaft Reflectivity

Skylight & Tubular Types only

The Reflectivity (%) of the Internal Surface of the Skylight Shaft

Shaft Refl % Column

Shaft Insulated

Skylight & Tubular Types only

Whether the Walls of the Skylight Shaft are insulated or not (simulated default is R2.0)

Shaft Insulated Column

Shaft Diffuser

Skylight & Tubular Types only

Whether the Bottom of the Skylight Shaft is fitted with a Diffuser Cover or not, or is open directly into the Zone.

Shaft Diffuser Column

...

The Skylight Library holds the complete library of all Skylight & Roof Window Specifications available for NatHERS Simulation. The Selected Skylight list within the Library is what is presented to Users within the Skylight Data-Grid’s Specification column (as well as filtering by Skylight Type).

Info

Further Information: Skylight Library