Openings are created using the Opening Drawing Draw Mode
...
Selecting
You can Select an Opening either within the Visual View or the Data-Grid.
...
Openings can be split using the Split & Merge Drawing Mode
Windows can be Split to model different Specifications for different portions of a Window such as Splitting a Window into it’s Fixed & Awning portions so that the Fixed & Awning Window portions can have a Fixed & Awning Type Window Specification applied to them from the Window Library.
This can also make it easier for Users, Window Manufacturers & Builders to evaluate & select the appropriate Window Suites to use for the project.
...
Property | Description | Edited Within | |||||
---|---|---|---|---|---|---|---|
Name | The Name of the Opening. The Opening’s Name is numerically incremented during creation (e.g. from W01 to W02 to W03) and so it can be useful to create Openings based on their Window Schedule tag (if available) so you do not need to rename the Openings. | Opening Data-Grid Name Column | |||||
Type | The Type of the Opening: Window, Door or Permanent | Type Column | |||||
Specification | Windows & Doors only The Specification of the Window or Door. Window SpecificationThe available Window Specifications within the Opening Data-Grid Specification Column is based on the Window Library Selected Windows List. Door SpecificationThere a variety of Door Specifications available within Hero including standard timber, insulated, metal & insulated metal Doors as well as two Opaque Louvres specifications.
| Specification Column | |||||
Orientation | The Orientation of the Opening (i.e. it’s normal direction or direction it is facing) | Not Editable | |||||
ViWidth | The Width of the Opening (in mm) | Visual View & Width Column | |||||
Left Offset | The Distance from the Left Edge of the Parent Wall to the Left Edge of the Opening (in mm) | Visual View & Left Offset Column (hidden by Default) | |||||
Total Height | The Total Height of the Opening (in mm). (I.e. Head Height - Sill Height) | Total Height Column | |||||
Head Height | The Head/Top Height of the Opening (in mm) above the Level’s Reference Height | Head Height Column | |||||
Sill Height | The Sill/Bottom Height of the Opening (in mm) above the Level’s Reference Height | Sill Height Column (hidden by Default) | |||||
Opening Style | Windows Only The Opening Style of the Window (e.g. Casement, Louvre, Awning etc). Changing the Opening Style will typically update the Openable Percentage of the Window | Opening Style Column | |||||
Openable Percentage | The Percentage of the Opening’s Area that is Openable for Ventilation as per NatHERS Technical Note Guidance
| Openable Column | |||||
Weatherstripped | External Windows & Doors only Whether the Window or Door has Weatherstripping or Draught-proofing specified to signficantly reduce air-leakage. | Weatherstripped Column | |||||
Insect Screen | External Windows & Doors only Whether the Window or Door is fitted within fixed Insect Screens. Insect Screens within a Chenath Simulation reduce Ventilation rates through Openings but do not effect modelled Solar Heat Gains or Heat Transfer. | Insect Screen Column | |||||
Frame External Colour | External Windows & Doors only The External Colour (and Solar Absorptance) of the Window or Door Frame | External Colour Column | |||||
Internal Shade | Windows only The Internal Shade device for the Window as specified & noted on the Plans, and it’s effective R-Value, Solar Transmittance (ST) & Solar Absorptance (SA) | Internal Shade Column | |||||
External Shade | Windows only The External Shade device for the Window as specified & noted on the Plans, and it’s effective Shading Coefficient (SC) | External Shade Column |
...
The Window Library holds the complete library of all Window Specifications available for NatHERS Simulation. The Selected Windows list within the Library is what is presented to Users within the Opening Data-Grid’s Specification column.
Info |
---|
Further Information: Window Library |