CEILINGS WITHIN THE DATA-GRID
Property | Description | Edited Within | |||
---|---|---|---|---|---|
Assembly | Hero has a variety of Ceilings Assemblies that can be used, and these are visible within the Construction column of the Ceiling Data-Grid. The current Assemblies include assemblies of the following Types:
|
Construction Column | |
Type | In addition to the Construction or Assembly of the Ceiling, the Ceiling Data-Grid also contains a Type column that is used for reference & information but that if changed may change both the Assembly and Adjacency Type to the relevant defaults for that Type as required. See above Assembly row for details. |
---|
Type Column | ||
Ceiling Insulation | A Ceiling has two Insulation Options, Ceiling & Roof, that are positioned accordingly within the Assembly. This feature was implemented to enable flexibility & rapid design changes to both common Insulation locations within the Hero interface. The Ceiling Insulation Option is the Insulation Material(s):
The Roof Insulation is the Insulation Material(s):
| Ceiling |
---|
Insulation Column | |
Roof Insulation | The Roof Insulation of the Ceiling. See above Ceiling Insulation section for details. |
---|
Roof Insulation Column | |
Ceiling Pitch | For raked or sloped ceilings within a Zone, the Pitch can be entered in degrees. This is the Internal Pitch of the Internal Ceiling Layer of the Ceiling, and not the pitch of the External Roof. The Pitch of the External Roof of a Ceiling is set by Hero automatically and cannot currently be adjusted. The Pitched Area of a Ceiling is shown in the Data-Grid Area column in square metres and represents gross area not accounting for any Skylight area. The Area is the Pitched Area, in that any Pitch entered in the Pitch column will automatically adjust the 2D Area of the Ceiling to account for the increase in area by any slope or raked Ceiling. E.g. In a Zone with 100m2 floor area, if the Ceiling Pitch was entered in the Ceiling Pitch column as 30 degrees, then the Area automatically adjusts to 115.5m2 |
---|
Pitch Column | ||
Area (Pitched Area) | The Pitched Area (see above) of the Ceiling in Square Metres. Can only be adjusted as the Ceiling is moved & adjusted within the Visual View. | Visual View |
---|
External Colour | The External Colour (and it’s associated Solar Absorptance) of a Ceiling can be selected within the External Colour column of the Ceiling Data-Grid. |
---|
Colour Column | |
Adjacency | The Adjacency Type of the Ceiling (see below for full details) |
---|
Adjacency Column | |
Roofspace Ventilation | Ceilings with a Roofspace Adjacency can toggle the Ventilation Rate of that Roofspace Zone through the Ventilation column of the Ceiling Data-Grid. Roofpsace Zones & Ventilation Rates are described in further detail in the Zones section. |
---|
Roofspace Ventilation Column |
...
Adjacency Types
Similar to Walls & Floors, Ceilings have a variety of different Adjacency Conditions that are determined by whether the Ceiling is adjacent to actual model objects or that can be selected manually be the user.
...